Original Keyence Fs-N41p Fs-N42p Digital Pressure Sensor Optic Digital Fibre Sensors Fs-N41n Fs-N41c
Product Details
| Customization: | Available |
|---|---|
| Description: | Fiber Optic Sensor |
| Model Number: | Fs-N41p |
Secured Trading Service
Diamond Member Since 2023
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Address
Chengdu, Sichuan, China
International Commercial Terms(Incoterms)
FOB, EXW, CFR, CIF, DAT, FAS, DDP, DAP, CIP, CPT, Others
Terms of Payment
LC, T/T, PayPal, Western Union, Small-amount payment, Money Gram, xtransfer
Find Similar Products
Basic Info.
- Model NO.
- FS-N41P FS-N42P
- Series
- Fs
- Output
- NPN, PNP, Relay No, Relay Nc
- Warranty
- 1 Year
- Transport Package
- Cartons
- Specification
- Customized
- Trademark
- Keyence
- Origin
- Japan
Product Description
|
Model
|
FS-N41C*1
|
|||
|
Type
|
M8 Connector*2
|
|||
|
Main unit/expansion unit
|
Main unit
|
|||
|
Response time
|
23 µs (S-HSPD*3)/50 µs (HSPD*4) / 250 µs (FINE) / 500 µs (TURBO) / 1 ms (SUPER) / 4 ms (ULTRA) / 16 ms (MEGA) / 64 ms (TERA)
|
|||
|
Number of control outputs
|
2*5
|
|||
|
Number of external inputs
|
1*5
|
|||
|
Light source LED
|
Transmitter side: Red, four-element LED (wavelength 660 nm)
|
|||
|
Control output
|
Open-collector, 30 V or less 100 mA or less per output,
100 mA or less total for 2 outputs (when used as a solitary unit) / 20 mA or less (when used as an expansion unit) Residual voltage NPN 1.4 V or less (output current 10 mA or less) / 2 V or less (output current 10 to 100 mA) PNP 1.6 V or less (output current 10 mA or less) / 2.2 V or less (output current 10 to 100 mA) |
|||
|
External input
|
Input time 2 ms (ON) / 20 ms (OFF) or longer*6
|
|||
|
Protection circuit
|
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection
|
|||
|
Mutual interference prevention
|
S-HSPD/HSPD 0 units, FINE 4 units, TURBO/SUPER/ULTRA/MEGA/TERA 8 units
(The mutual interference prevention values are twice those shown here when Double is set.) |
|||
|
Power supply
|
Power voltage
|
10 to 30 VDC (including 10% ripple (P-P) or less) , class 2 or LPS*7
|
||
|
Current consumption
|
During normal operation: 910 mW or less (36 mA or less at 24 V/65 mA or less at 12 V)
ECO ON: 840 mW or less (33 mA or less at 24 V/60 mA or less at 12 V) ECO FULL: 750 mW or less (30 mA or less at 24 V/52 mA or less at 12 V)*8 |
|||
|
Environmental resistance
|
Ambient light
|
Incandescent lamp: 20,000 lux or less, sunlight: 30,000 lux or less
|
||
|
Ambient temperature
|
-20 °C to +55 °C (no freezing)*9
|
|||
|
Vibration resistance
|
10 to 55 Hz; double amplitude 1.5 mm; 2 hours each for X, Y, and Z axes
|
|||
|
Shock resistance
|
500 m/s2 ; 3 times each for X, Y, and Z axes
|
|||
|
Case material
|
Main unit and cover: polycarbonate
|
|||
|
Weight
|
Approx. 25 g
|
|||
|
*1 IO-Link Specification V.1.1/COM2 (38.4 kbps) is supported.
*2 Ensure the cable length is 30 m or less for the M8 connector type. Ensure the cable length is 20 meters or less when connecting by way of IO-Link. *3 Restrictions when S-HSPD is selected Output 2 of dual output types is fixed to OFF. IO-Link communication cannot be used. Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *4 Restrictions when HSPD is selected Display Gain cannot be used. *5 Output 2 and the external input are selectable. *6 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *7 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *8 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *9 When expanded by 1 to 2 units: -20 °C to +55 °C. When expanded by 3 to 10 units: -20 °C to +50 °C. When expanded by 11 to 16 units: -20 °C to +45 °C. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifier has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space. |
||||