Customization: | Available |
---|---|
After-sales Service: | User Guides |
Phase: | 3 Phase 3 Wire or 3 Phase 4 Wire |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1
|
Segment LCD(white backlight)
|
||
2
|
Available to measure voltage/current/active power /reactive power /frequency/power factor, etc, total 28 units.
|
||
3
|
RS485 communication,Modbus RTU procotol
|
||
4
|
Active/reactive Kwh/ four-quadrant Kvarh measured function, with pulse output port.
|
||
5
|
4 loop DI and 2 loop alarm output, input and output completely isolated, with remote control and telecommand functions.
|
||
6
|
Optional 1 loop 4 ~ 20mA analog output function.
|
||
7
|
3 phase voltage/current subharmonic measurement (2 ~ 32)
|
||
8
|
8 periods, 4 kinds of rate statistics function. (multi-rate function)
|
Model | Analog output | Alarm output | DI | RS485 | Multi-rate | Harmonic | Input range |
DW9L-RC38 | No | 2 loop | 4 loop | 1 loop | Yes | Yes | 10~480v(L-L) 0.02~6A |
DW9L-IRC38 | 4~20m | 2 loop | 4 loop | 1 loop | Yes | Yes |
Input signal
|
Input voltage
|
10~480V(L-L) each phase power consumption <1VA
|
Voltage impedance
|
≥300KΩ
|
|
Input current
|
0.02~6A each phase power consumption <0.4VA
|
|
Current impedance
|
<20mΩ
|
|
Rated frequency
|
50Hz,60Hz (To ensure the accuracy, pls advise the specific frequency range, if 60Hz~500Hz is needed.)
|
|
Accuracy
|
Active energy: 0.5S class Reactive energy: 2 class Voltage/current: 0.2%FS
|
|
Measured range
|
Current: 0.02A~6A Voltage: Phase voltage L-N:10~277V, wire voltage L-L: 10~480V
|
|
Electr-ical para-meter |
Relay capacity
|
AC 250V 5A DC24V 5A (Resistive load)
|
Analog output
|
DC 4~20mA Load<500Ω
|
|
Display device
|
Industrial segment LCD display Clock accuracy: <0.5 second per day
|
|
DI
|
Dry contact input Input voltage
|
|
Communication
|
Communication port
|
RS485 port(Modbus RTU procotol,and DL/645 procotola) Baud trate: 4.8kbps /9.6kbps (19.2kbps can be ordered)
|
Pulse output
|
1 loop energy pulse output (PhotoMOS relay) Pulse constant 9000imp/kwh
|
|
EMC
|
ESD
|
IEC/EN61000-4-2 Air±8KV/Contact ±6KV perf.Criteria B
|
Pulse train
|
IEC/EN61000-4-4 ±4KV perf.Criteria B
|
|
Frequency drop
|
IEC/EN61000-4-11 0%-70% perf.Criteria B
|
|
Lightning surge
|
IEC/EN61000-4-5 ±2KV/±4KV perf.Criteria B
|
|
Radiated emission
|
CISPR22/EN55022 CLASS B
|
|
Conducted emission
|
CISPR22/EN55022 CLASS B
|
|
Radiated immunity
|
IEC/EN61000-4-3 10V/M perf.Criteria A
|
|
Conducted immunity
|
IEC/EN61000-4-6 10 Vr.m.s perf.Criteria A
|
|
Power frequency immunity
|
IEC/EN61000-4-8 10A/M perf.Criteria A
|
|
Environment
|
Working environment
|
Temperature range: 0ºC~50ºC Limit condition-10ºC~55ºC Humidity range: 5~90%R.H(no condensation)
|
Storage temperature
|
-25ºC~60ºC
|
|
Shell specifications |
Material
|
VO class flame retardant, PC+ABS, PC panel Protection level IP65(front panel)
Insulation resistance: input/output/power against shell>100MΩ
|
Shockproof
|
10~57Hz (XYZ direction 2G/30 minutes)
|
|
Power
|
Power voltage
|
AC/DC 100~240V 50/60Hz Power consumption<7VA
|
|
Withstand voltagew
|
Input signal and power 2000 VAC,input and output 2000 VAC,power and analog output, RS485 port,pulse output port≥AC 2000V
|
Weight
|
About 0.6kg
|