Customization: | Available |
---|---|
Usage: | Ray Sensor |
Model Number: | Fs-N41n |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model
|
FS-N41N
|
|||
Type
|
Cable
|
|||
Output
|
NPN
|
|||
Main unit/expansion unit
|
Main unit
|
|||
Number of control outputs
|
1
|
|||
Number of external inputs
|
―
|
|||
Light source LED
|
Transmitter side: Red, four-element LED (wavelength: 660 nm)
|
|||
Response time
|
23 µs (S-HSPD*1) /50 µs (HSPD*2) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) /64 ms (TERA)
|
|||
Control output
|
Open-collector, 30 V or less 100 mA or less per output,
100 mA or less total for 2 outputs (when used as a solitary unit) /20 mA or less (when used as an expansion unit) Residual voltage: 1.4 V or less (output current: 10 mA or less) /2 V or less (output current: 10 to 100 mA) |
|||
External input
|
Input time: 2 ms (ON) /20 ms (OFF) or longer*3
|
|||
Unit expansion
|
Up to 16 units (17 units connected in total including the main unit) . However, each dual output type will be treated as two
expansion units. |
|||
Protection circuit
|
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection
|
|||
Mutual interference prevention
|
S-HSPD/HSPD: 0 units, FINE: 4 units, TURBO/SUPER/ULTRA/MEGA/TERA: 8 units (The mutual interference prevention values are twice
those shown here when Double is set.) |
|||
Power supply
|
Power voltage
|
10 to 30 VDC (including 10 % ripple (P-P) or less) , class 2 or LPS*4
|
||
Power consumption
|
During normal operation: 870 mW or less (34 mA or less at 24 V/62 mA or less at 12 V)
ECO ON: 800 mW or less (31 mA or less at 24 V/56 mA or less at 12 V) ECO FULL: 710 mW or less (28 mA or less at 24 V/49 mA or less at 12 V)*5 |
|||
Environmental resistance
|
Ambient light
|
Incandescent lamp: 20,000 lx or less, sunlight: 30,000 lx or less
|
||
Ambient temperature
|
-20 °C -4 °F to +55 °C +131 °F (no freezing)*6
|
|||
Vibration resistance
|
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes
|
|||
Shock resistance
|
500 m/s2; 3 times each for X, Y, and Z axes
|
|||
Case material
|
Main unit and cover: polycarbonate
|
|||
Weight
|
Approx. 78 g
|
|||
*1 Restrictions when S-HSPD is selected
Area detection, Area % Mode, DATUM, Rising edge, and Falling edge cannot be selected for Detection Mode. Output timer, Limit Detection, and Display Gain cannot be used. FULL cannot be selected for the ECO function. *2 Restrictions when HSPD is selected Display Gain cannot be used. *3 The input time becomes 25 ms (ON)/25 ms (OFF) when external calibration input is selected. *4 When expanding the system to 9 or more units, use a power supply voltage of 12 V or higher. *5 The load current is excluded. The power consumption including the load when the maximum number of units are connected is 38 W max. *6 When expanded by 1 to 2 units: -20°C -4°F to +55°C +131°F. When expanded by 3 to 10 units: -20°C -4°F to +50°C +122°F. When expanded by 11 to 16 units: -20°C -4°F to +45°C +113°F. When using 2 outputs, 1 unit is counted as 2 units. The prescribed values for the ambient temperature assume that the sensor amplifi er has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space. |